The quality of effluent (and life)

23 July 2011


Simon Judd

Simon Judd

Author Bio

Simon Judd, author of The MBR Book, Watermaths, and Industrial MBRs, offers observations on membrane technology. Contact Simon at simon@juddwater.com.

According to the great Tom Lehrer: “Life is like a sewer: what you get out of it depends on what you put in”. In which case, of course, wastewater treatment reflects life.

A big selling point of MBRs is the constant and high wastewater quality – so taken for granted that it hardly features at all in the discussion pages of The MBR Group on LinkedIn. What’s more, the membrane pore size hardly seems to make any difference: if there’s a lot of non-biodegradable dissolved organics in the feed they’ll end up in the permeate whether challenged with an MF or UF membrane. For suspended solids, there’s always complete removal either membrane type is used.

However, when it comes down to the sticky subject of viruses there is perhaps some room for debate. The UF suppliers will argue that only such a membrane has pores small enough to remove viruses. The MF suppliers will claim that the protective dynamic layer formed on the membrane ensures adequate virus rejection.

There are a few papers published on virus removal by MBRs. The general conclusion is that unassociated “free-swimming” viruses can penetrate an MF membrane (which isn’t too surprising) and will do so to a lesser extent with a UF membrane. However, under realistic operating conditions the viruses tend to associate themselves with the solids, which means that even a polishing sand filter can achieve 99% virus removal from secondary effluent if operated well. So, we’re pretty comfortable about virus breakthrough.

And yet there are still bacteriological positives measured in MBR effluent – simply, it seems, because the huge membrane surface areas encourage biofilm growth on the permeate side. The very thing that is providing high-quality product water is probably responsible for its (very minor and occasional) bacteriological contamination.

An irony which Mr Lehrer would have undoubtedly appreciated.

‘The MBR Site’ is a trading division of Judd and Judd Ltd, a company registered in England and Wales, registered number 8082403.

Registered office: Suite 2, Douglas House, 32-34 Simpson Road, Fenny Stratford, Buckinghamshire, MK1 1BA, United Kingdom. Email: info@thembrsite.com

Banner image: full treatment plant for pharmaceutical wastewater in Taizhou, Linhai Park, Zhejiang Province, China, including Shanghai MEGAVISION  flat sheet UF membrane modules in two MBR units. Image courtesy of VALORSABIO, Lda.

Image credits:

– Image for our Chinese largest plants 全球最大的MBR项目 homepage link: Image supplied by Apex Environmental
– Image for our Consultants and Contractors homepage link: Image supplied by Ovivo USA, LLC.

Disclaimer: The information given on this website is reproduced in good faith. No liability is accepted for errors or omissions. The MBR Site does not endorse any products, services, organisations, events or any other listing included in this site. You are strongly advised to check all information, including specifications and installation details, before acting on any information given in this website. The MBR Site links to third-party websites – note that we are not responsible for the content of third-party websites and third-party websites are visited at your own risk. Please read our terms and conditions and privacy policy. Use of this website indicates acceptance of these conditions.